Victron Energy charge controller BlueSolar MPPT 150/45 Mc4

457,00

In stock

SKU: VICRVAWY94 Category:

Description

Victron Energy charge controller BlueSolar MPPT 150/45 Mc4

Charge controller BlueSolar MPPT 150/45 12/24/48v and 45th is a MPPT ultrafast solar controller that has eight pre-programmed, selectable algorithms that maximize energy collection at all times. Includes internal temperature sensor to compensate for the charging voltage, absorption and flotation of the battery.

Charging current up to 45 amps and PV voltage up to 150 volts
  • The BlueSolar 150/45-Tr MPPT charge controller can charge a lower rated voltage battery from a higher rated voltage PV plate.
  • The controller will automatically adjust the nominal battery voltage to 12, 24, 36, or 48 V.
  • Exceptional conversion efficiency
  • No fan. Maximum efficiency exceeds 98%.
  • Flexible Load algorithm
  • Fully programmable load algorithm (see the Software page on our website), and eight pre-programmed algorithms, selectable with a rotary switch (see the Manual for details).
Extensive electronic protection
  • Protection against excess temperature and power decrease when the temperature is high.
  • PV Short circuit and PV reverse polarity protection.
  • PV reverse the current protection.
  • Internal temperature Sensor
  • Compensates for absorption and flotation load voltage for temperature.
Real-time Data display options
  • Apple and Android smartphones, tablets and other devices: see the VE. Direct to Bluetooth Smart dongle
  • ColorControl Panel
Controller Victron BlueSolar MPPT 150/45-MC4
  • Voltage 12/24/48 v Auto Select (software tool needed to select 36 V) Battery
  • Nominal current Load 45 A
  • Maximum power PV, 12v 1a, b) 650 W
  • Maximum power PV, 24v 1a, B) 1,300 W
  • Maximum power PV, 48v 1a, b) 2,600 W
PV Maximum Open circuit voltage
  • 150V absolute Maximum colder conditions
  • 145V start-up and maximum performance

Maximum Efficiency 98%

  • Self-consumption 10 MA
  • Charging voltage ' absorption ' default setting: 14.4/28.8/43.2/57.6 V (adjustable)
  • Load ' float ' voltage setting by default: 13.8/27.6/41.4/55.2 V (adjustable)
  • Multi-stage loading algorithm
  • Temperature compensation-16 MV/°c resp. -32 MV/°c
  • Battery protection Reverse polarity (fuse, not accessible to user)
  • PV Reverse polarity/short circuit/over temperature output
  • Operating temperature from-30 to + 60 ° C (total nominal power up to 40 °c)
  • Humidity 95%, non-condensing
  • Data communication port and remote control on/off VE. Direct (see the data communication document on our web page)
  • Synchronized parallel operation is not possible
BlueSolar MPPT 150/45 Load Controller body
  • Blue Color (RAL 5012)
  • PV 2 Terminals) 35 mm ²/AWG2 (TR models), or Dual MC4 connectors (MC4 models)
  • Battery terminals 35 mm ²/AWG2
  • Degree of protection IP43 (electronic components), IP22 (connection area)
  • Weight 3 kg
  • Dimensions (H x W x D) 200 x 250 x 95 mm
Regulations
  • Security EN/IEC 62109
  • 1a) If more than one photovoltaic power is connected, the controller will limit the input power to the maximum set.
  • 1b) voltage PV must exceed Vbat + 5v for the controller to start.
  •  Thereafter minimum voltage PV is Vbat + 1v
  • 2) MC4 models: will be needed several parallel of solar panels

DATA SHEET 

 

Additional information

Weight 4,0000 kg