Description
Midnite Mini DC Plus 250 Amp Model
Midnites enhanced version of the ever popular Mini DC Disconnect Breaker Box
Image shows 125 amp breaker 175a & 250 a breakers are much larger
The MNDC Plus version of the popular MNDC adds another din rail allowing up to ten din rail mount breakers. Two din rail cover plates and two panel mount plates are included. The panel mount plates allow for mounting the ¾” 125VDC breakers that range from 60 amps to 100 amps. You can also fit the MNDC-GFP80 plus four more panel mount breakers in the enclosure. Another configuration would be one MNDC-GFP, one ¾” panel mount breaker and five din rail breakers as well as the large 125-250A inverter breaker. Mounting is provided for a 500 amp shunt and a MNTBB-R terminal bus bar. Battery negative stud is included as well as a ground busbar.
The DC 250 Breaker is usually used in 12 and 24 volt systems where main battery cable to Inverter charger are correctly sized at 70mm2 and above. For 48v systems where 50mm2 cabling is used then the 175 amp beaker is used and the 125 amp breaker is used with 35mm2 cabling